Recent content by Elisa Cresto

  1. E

    Sapphire Use with DRC Wireless

    Are there any plans to have the Sapphire be able to be used with the DRDC Wireless system? We see the Lutron Vive wireless system spec'd with their touchscreen quite often, and always either have to take exception, or offer a wired solution that often times does not get approved against wireless.
  2. E

    Provolt

    Hi Reid, Your wiring diagram shows two room controller sensors in conjunction with each other. What about using the sensors that are NOT listed as room controllers that come up when you search for ProVolt on our website? I.e. I have a room that is one zone, with multiple ceiling mount...
  3. E

    Pillow Speaker Control with DRC

    Customer is saying that a layout received from Leviton (I believe by a TSS or RSM), had DRC AI inputs placed in patient rooms to provide a contact closure input for the pillow speaker control. I know this is possible with our GreenMAX system, operating as a dry contact closure, but am not sure...
  4. E

    EM with GreenMAX

    There are 2 ways to do EM with GreenMAX: Return to Close (RTC) upon loss of power Programmatically force levels when the EM input is triggered. Return To Close (RTC) Upon Loss Of Power Only applicable for power loss situations Triggers when the GreenMAX brain loses power Only works for...
  5. E

    DRC Analog Input Device

    Two follow up questions: I have a project where we did not supply any EM/UL924 devices, but are using a Sapphire as the room controller, and customer has confirmed that the system is networked – will the above described fire alarm input work? Or do I need EM Smart Packs in order for it to work...
  6. E

    4-button Functionality for distributed SP GreenMAX system

    So, overarching statement, Leviton does not have any button stations in either the DRC or GreenMAX (relay and smart pack types) worlds that can do ON/press hold to raise / OFF/press hold to lower. Is that correct?
  7. E

    4-button Functionality for distributed SP GreenMAX system

    With the DRC push buttons, could I do a 2-button with the 2 scenes called out on them and then a 4-button for on/off raise/lower? Multiple zones tied to those two button stations?
  8. E

    4-button Functionality for distributed SP GreenMAX system

    If it was GreenMAX DRC button stations, would that be a supported functionality?
  9. E

    4-button Functionality for distributed SP GreenMAX system

    GreenMAX Relay panel button stations - RDGSW's.
  10. E

    4-button Functionality for distributed SP GreenMAX system

    Can we meet the requested functionality for GreenMAX 4-button stations? These are part of a distributed smart pack system, with sapphires in the spaces as well. "4-button wall station with custom engraving: 1. "ON" (press and hold for raise) 2. "Meeting" 3. "Presentation" 4. "OFF" (press and...
  11. E

    Concerns regarding ethernet port in GM Panel

    End user raised some concern over the "open-ness" of the ethernet port utilized in our GreenMAX relay panel, as the project is on a military base. Customer wants to know "how the ethernet port is used", and if there "is anything you have that shows this port if merely used for connection to...